Illinois Urban Manual
Material Specifications
544. CLAY PIPE AND DRAIN TILE
1. SCOPE
This specification covers the quality of clay pipe and drain tile.
2. PIPE
Standard strength clay pipe and extra strength clay pipe shall conform to
the requirements of ASTM Specification C 700 for the specified class of pipe.
3. PERFORATED PIPE
Perforated clay pipe shall conform to the requirements of ASTM
Specification C 700 for the specified class of pipe.
4. DRAIN TILE
Clay drain tile shall conform to the requirements of ASTM Specification C 4
for the specified class of tile. Perforated drain tile shall conform to the
requirements of ASTM Specification C 498 for the specified class.
5. COMPRESSION JOINT MATERIAL
Compression joints using material having resilient properties shall conform
to the requirements of ASTM Specification C 425.
Specification Date 10/98