Illinois Urban Manual
Material Specifications
531. PORTLAND CEMENT
1. SCOPE
This specification covers the quality of portland cement.
2. QUALITY
Portland cement shall conform to the requirements of ASTM Specification C
150 for the specific types of cement. When Type I portland cement is
specified, Type IS portland blast-furnace slag cement or Type IP
portland-pozzolan cement conforming to the requirements of ASTM Specification
C 595 may be used unless prohibited by the specifications.
When air-entraining cement is required, the Contractor shall furnish the
manufacturers written statement providing the source, amount and brand name of
the air-entraining component.
3. STORAGE AT THE CONSTRUCTION SITE
Cement shall be stored and protected at all times from weather, dampness or
other destructive elements. Cement that is partially hydrated or otherwise
damaged will not be accepted.
Specification Date
10/98
Return
to Top of Page
< Back to Table of Contents
|